M-95 Spec Sheet:
Spec Sheet | Drawings | Literature
You can copy and paste this information into your word processor.
Enclosure
NEMA 4X FRP (Fiberglass reinforced polyester)
18" H x 16" W x 9" D
Two (2) padlockable stainless steel latches
Power Required
120 VAC / i PH / 60 HZ (Standard)
Circuit Breaker
20 AMP
Motor
1/2 H.P. 100% continuous duty cycle, TEFC, 1.15 Service Factor
Pump
Fixed displacement steel gear(Flow rates from 0.24 - 1.15 G.P.M.)
Bypass Relief
Adjustable to operating system requirements
Pressure Settings
Variable 100 - 2,000 P.S.I.
Pressure Switch
Adjustable to operating system requirements
Pressure Gauge
2.5" liquid filled 0 - 3,000 P.S.I.
System Timer
0 - 10 minutes
Tank Level Switch
Single Pole Double Throw
Operating Modes
"REMOTE" / "OPEN" / "CLOSE"
Manual Controls
"OPEN"
"CLOSE"
"EMERGENCY STOP" palm button
Diagnostic Lights
"Breaker ON"
"Power ON"
"Remote"
"Open"
"Close"
"E-Stop engaged"
Weight
65 Lbs. (Dry)