PA-90D Spec Sheet:
Spec Sheet | Drawings | Literature
You can copy and paste this information into your word processor.
Enclosure
NEMA 4X FRP (fiberglass reinforced polyester) padlockable.
16" H x 14" W x 6"D
NEMA 4 carbon steel and NEMA 4X stainless steel are optionally available. (Size will depend upon overall system requirements and customer specification).
Power Required
120 VAC / 1 PH / 60 HZ (Standard)
Circuit Breaker
Sized to pump and motor requirements. (10 amp standard).
Compressor
1.0 CFM @ 80-psig
Pressure Settings
Pump "ON" @ 80 P.S.I Pump
"OFF" @ 100 P.S.I.
Pressure Gauge
2.5" 0 – 160 psig. Internally mounted.
System Timer
0 - 10 minutes adjustable.
Bypass Relief
Adjustable to system operating requirements. (Typically set @ 110-psig)
Pressure Switch
120-vac with “auto-unloader”
Operating Modes
"REMOTE" / "LOCAL"
Manual Controls
"OPEN"
"CLOSE"
"EMERGENCY STOP" palm button
Diagnostic Lights
"Breaker ON"
"Power ON"
"Remote"
"Open"
"Close"
"E-Stop engaged"
Weight
25 Lbs. Standard.
Custom systems will vary depending upon overall system configuration.